+91-9811347199 saurabh.joshi@fanair.in
/// ESTD 2016

Fans Section in Mumbai

Fan Sections Manufacturers in Mumbai

Efficient Airflow Solutions for HVAC Systems

Fan sections are essential components of HVAC and air handling systems. They contain fan equipment designed to move air through ventilation systems, air handling units, and packaged HVAC equipment. Depending on the application, different fan configurations may be selected to provide the specified airflow and pressure.

For commercial, industrial, and HVAC projects, Fan Sections Manufacturers in Mumbai offer ready-to-install solutions with Plug Fans and Mixed Flow Fans. These fan sections are designed for different airflow requirements and can be integrated into AHUs, existing AHU retrofits, and packaged HVAC equipment.

Contact Us
Plug Fans Manufacturers in Mumbai

Plug Fans

Integrating directly into ductwork or equipment, our bifurcated fans offer compact design and flexible installation options for space-constrained applications. With efficient airflow delivery and quiet operation, our fans ensure optimal performance and comfort in HVAC systems and industrial environments.

Size
315MM to 1600 MM
Capacity
Upto 1,30,000 CMH
Static Pressure
Upto 40 mmwg
Impeller
Adjustable Pitch Impeller
Mixed Flow Fans Manufacturers in Mumbai
Mixed Flow Fans

Combining features of axial and centrifugal fans, our mixed flow fans provide a balance of airflow and pressure for various applications. From HVAC systems to industrial processes, our fans deliver reliable performance and energy efficiency in diverse environments.

Impeller
Backward curved impeller to achieve higher efficiency & lower noise level. Integration of impeller with external rotor motor is kept in mind while designing the fans.
Applications
Toilet, hotel, auditorium, station, supermarket, airport and other public occasions.
Aspects
Bulk, weight, vibration, noise, durability, efficiency and safety

What Are Fan Sections?

A fan section is an integrated part of an HVAC or air-handling system that contains the fan required to move air through the system or ductwork. It offers a controlled airflow path and may be configured according to the requirements of the whole ventilation system.

Fan Sections in Mumbai are available in different configurations for commercial buildings, industrial facilities, and other HVAC applications. Plug fans provide a compact solution for integration into ductwork or equipment, while mixed flow fans integrate features of axial and centrifugal fan designs.

Plug Fans

Plug fans are designed to integrate directly into ductwork or HVAC equipment. Their compact construction makes them suitable for installations where available space is limited.

The current Mumbai range includes Plug Fans from 315 mm to 1600 mm, with capacity up to 1,30,000 CMH and static pressure up to 40 mmWG. The fans use adjustable pitch impellers, allowing the configuration to be selected according to airflow requirements.

Mixed Flow Fans

Mixed flow fans integrate characteristics of axial and centrifugal fans. This allows them to provide a balance between airflow and pressure for different ventilation applications.

The current design uses a backward-curved impeller to achieve better efficiency and lower noise. The impeller is designed with integration of an external rotor motor in mind. These fans are suitable for washrooms, hotels, auditoriums, stations, supermarkets, airports, and other public spaces.

Key Features of Fan Sections

Fan Sections in Mumbai may be configured according to specific HVAC and ventilation requirements. Important features include:

  • Plug Fan and Mixed Flow Fan options
  • Compact construction
  • Direct integration into ductwork or equipment
  • Adjustable pitch impeller for Plug Fans
  • Backward-curved impeller for Mixed Flow Fans
  • Airflow capacity up to 1,30,000 CMH
  • Static pressure up to 40 mmWG
  • Suitable for AHU integration
  • Ready-to-install configurations
  • Suitable for AHU retrofit projects
  • Suitable for packaged HVAC equipment
  • Low-noise airflow options
  • Focus on performance, vibration, durability, and protection

The current product page also highlights essential selection factors such as bulk, weight, vibration, noise, durability, performance, and protection while considering fan section configurations.

Technical Specifications

Fan Section TypesPlug Fans & Mixed Flow Fans
Plug Fan Size315 mm to 1600 mm
Plug Fan CapacityUp to 1,30,000 CMH
Static PressureUp to 40 mmWG
Plug Fan ImpellerAdjustable Pitch
Mixed Flow ImpellerBackward Curved
Motor IntegrationExternal Rotor Motor
InstallationAHUs, HVAC Equipment & Ductwork
ApplicationsCommercial, Industrial & Public Spaces

The final fan section configuration should be selected according to required airflow, static pressure, available space, application, and site conditions.

Applications of Fan Sections

Industrial Fan Sections can be used in a wide variety of industrial and commercial HVAC systems.

Air Handling Units

Fan sections can be incorporated into AHUs to offer the specified air movement through the unit. Plug fans provide a compact arrangement that may be appropriate for equipment-based installations.

AHU Retrofits

Existing air handling units may also require replacement or upgrading of their fan sections. Ready-to-install fan configurations can be used for retrofit projects when properly sized according to the existing system.

Packaged HVAC Equipment

Fan sections also can be integrated into packaged HVAC equipment. The appropriate fan type and capacity depend on the airflow and static pressure requirements of the system.

Hotels and Public Buildings

Mixed flow fans can be used in hotels, auditoriums, stations, supermarkets, airports, washrooms, and other public spaces where controlled ventilation is required.

Industrial Facilities

Industrial facilities often require continuous air movement for ventilation and process requirements. Fan sections can be selected according to the airflow and pressure needed through the system.

Benefits of Fan Sections

One of the main benefits of fan sections is their ability to offer a compact and organised airflow solution within HVAC equipment. Plug fans can integrate directly into ductwork or equipment, which can be useful when installation space is limited.

Mixed flow fans provide a balance between airflow and pressure. Their backward-curved impeller design is intended to support better efficiency and lower noise.

Another advantage is the availability of various sizes and configurations. This allows the fan section to be selected according to the requirements of new HVAC systems, existing AHU retrofits, and packaged equipment.

Proper selection can also take into account factors such as vibration, noise, durability, efficiency, bulk, weight, and safety.

Fan Sections Suppliers in Mumbai

Choosing appropriate Fan Sections Suppliers in Mumbai is essential because the fan section needs to fit the requirements of the whole HVAC system.

The selection should consider airflow, static pressure, available installation area, fan type, application, and operating conditions. For retrofit projects, the existing AHU dimensions and system requirements should also be checked before selecting the replacement fan section.

The current Mumbai site states that fan sections are selected according to required airflow, static pressure, and site conditions. Technical sizing and data may be supplied before ordering, with completed equipment dispatched to Mumbai and other parts of India.

Mumbai and the broader MMR area, such as Thane, Navi Mumbai, Taloja MIDC, and Bhiwandi, have applications across high-rise buildings, malls, hospitals, data centres, pharmaceutical and chemical plants, and large warehouses.

Fan Sections Manufacturer in India

A reliable Fan Sections Manufacturer in India should be able to provide different fan configurations for HVAC, commercial, industrial, and public-space applications.

The current Mumbai range is manufactured at the factory in Neemrana, Rajasthan, and supplied to project sites in Mumbai and other places across India. Technical support is available for sizing and selection before ordering.

Manufacturing and selection should be based on the actual airflow, static pressure, available space, and application requirements of the project.

How to Choose the Right Fan Section?

Before selecting a fan section, consider the following factors:

  • Airflow requirement: Determine the volume of air the system needs to move.
  • Static pressure: Check the pressure required to overcome system resistance.
  • Fan type: Select Plug Fan or Mixed Flow Fan according to the application.
  • Available space: Check the installation dimensions inside the AHU or HVAC system.
  • Application: Identify whether the fan section is for a new system, AHU retrofit, or packaged system.
  • Noise: Consider acoustic requirements, especially for hotels, offices, hospitals, and public areas.
  • Vibration: Proper selection and installation are vital for smooth operation.
  • Operating environment: Consider dust, moisture, temperature, and other site conditions.

Correct sizing helps the fan section integrate well with the entire HVAC and ventilation system.

FAQs

What are fan sections used for?

Fan sections are used in air handling units, AHU retrofits, packaged HVAC equipment, and ventilation systems to offer controlled air movement.

What types of fan sections are available?

The current Mumbai range includes Plug Fans and Mixed Flow Fans. Plug fans offer compact integration, while mixed flow fans combine axial and centrifugal characteristics.

What is the size range of Plug Fans?

The listed Plug fan size range is 315 mm to 1600 mm, with capacity up to 1,30,000 CMH and static pressure up to 40 mmWG.

What type of impeller is used in Plug Fans?

The Plug Fans use an adjustable pitch impeller, which allows the fan configuration to be selected according to the specified airflow.

Where are Mixed Flow Fans used?

Mixed Flow Fans may be used in washrooms, hotels, auditoriums, stations, supermarkets, airports, and other public spaces. They can also be applied to suitable HVAC and commercial ventilation systems.

Conclusion

Fan Sections Manufacturers in Mumbai offer compact and flexible airflow solutions for AHUs, HVAC equipment, AHU retrofit projects, commercial buildings, industrial facilities, and public areas. With Plug Fan and Mixed Flow Fan configurations, different sizes, adjustable pitch impellers, and backward-curved impeller options, these systems can be selected according to different airflow and pressure requirements.

With a listed Plug Fan range of 315 mm to 1600 mm, capacity up to 1,30,000 CMH, and static pressure up to 40 mmWG, the equipment may be configured for a wide range of applications. FanAir India Pvt. Ltd. manufactures and supplies fan sections for Mumbai, the broader MMR area, and other locations across India, with technical sizing based on airflow, static pressure, and location conditions.

Contact Us

Serving Mumbai

Fan Air India Pvt. Ltd. manufactures ready-to-install fan sections with plug and mixed-flow fans. For customers in Mumbai, our Fan Sections are commonly used for air handling units, retrofits of existing AHUs and packaged HVAC equipment.

Mumbai and the surrounding MMR region, including Thane, Navi Mumbai, the Taloja MIDC estate and the Bhiwandi logistics belt, hosts high-rise towers, malls, hospitals, data centres, pharmaceutical and chemical units and large warehouses. Deep basement car parks and the humid coastal climate place high demands on ventilation and fire-safety systems.

Every unit is built at our factory in Neemrana, Rajasthan and selected to suit the required airflow, static pressure and site conditions of your project. Our team can help with sizing and technical data before you order, and we dispatch finished equipment to sites across Mumbai and the rest of India.

To get a quotation for Fan Sections in Mumbai, share your airflow, pressure and application details through our contact page, call +91-9811347199 or email saurabh.joshi@fanair.in.

Other Fan Air products in Mumbai

Fan Sections in other locations