+91-9811347199 saurabh.joshi@fanair.in
/// ESTD 2016

Fans Section in Delhi

Fan Sections Manufacturers in Delhi

Efficient Airflow Solutions for HVAC Systems

Fan sections are important components of current HVAC and air handling systems. They help provide controlled airflow inside air handling units, packaged HVAC equipment, and other ventilation systems. Depending on the application, fan sections can use different fan types to achieve the specified airflow and pressure.

For commercial and industrial ventilation projects, Fan Sections Manufacturers in Delhi provide ready-to-install solutions with specific sizes and configurations. Plug fans and mixed flow fans can be selected according to the specified airflow, static pressure, available space, and installation conditions. These solutions are also suitable for new HVAC systems as well as upgrades and retrofits.

Contact Us
Plug Fans Manufacturers in Delhi

Plug Fans

Integrating directly into ductwork or equipment, our bifurcated fans offer compact design and flexible installation options for space-constrained applications. With efficient airflow delivery and quiet operation, our fans ensure optimal performance and comfort in HVAC systems and industrial environments.

Size
315MM to 1600 MM
Capacity
Upto 1,30,000 CMH
Static Pressure
Upto 40 mmwg
Impeller
Adjustable Pitch Impeller
Mixed Flow Fans Manufacturers in Delhi
Mixed Flow Fans

Combining features of axial and centrifugal fans, our mixed flow fans provide a balance of airflow and pressure for various applications. From HVAC systems to industrial processes, our fans deliver reliable performance and energy efficiency in diverse environments.

Impeller
Backward curved impeller to achieve higher efficiency & lower noise level. Integration of impeller with external rotor motor is kept in mind while designing the fans.
Applications
Toilet, hotel, auditorium, station, supermarket, airport and other public occasions.
Aspects
Bulk, weight, vibration, noise, durability, efficiency and safety

What Are Fan Sections?

A fan section is part of an air handling or ventilation system that includes the fan and related components required to move air through the system. It can be integrated into an AHU, packaged HVAC equipment, or existing ventilation setup.

Fan sections help create a compact and organised airflow arrangement. The selection of the fan type depends on the required air volume, pressure, space, noise level, and application.

Plug Fans

Plug fans are designed to integrate directly into ductwork or equipment. Their compact construction makes them appropriate for installations where available space is limited.

The Delhi range includes plug fan sections with 315 mm to 1600 mm sizes, capacity up to 1,30,000 CMH, and static pressure up to 40 mmWG. The fans are equipped with adjustable pitch impellers to suit different airflow requirements.

Mixed Flow Fans

Mixed flow fans integrate features of axial and centrifugal fan designs. This allows them to provide a balance between airflow and pressure while maintaining a compact arrangement.

The mixed flow fan design uses a backward-curved impeller to support better performance and lower noise. The impeller is also designed with integration of an external rotor motor in mind. These fans may be used in washrooms, hotels, auditoriums, stations, supermarkets, airports, and other public areas.

Key Features of Fan Sections

Fan Sections in Delhi can be configured according to the requirements of different HVAC and ventilation systems. Some essential features include:

  • Compact and practical construction
  • Plug fan and mixed flow fan options
  • Adjustable pitch impeller for plug fans
  • Backward-curved impeller for mixed flow fans
  • Suitable for AHU integration
  • Ready-to-install configurations
  • Different sizes and airflow capacities
  • Suitable for new installations and retrofits
  • Focus on airflow, pressure, noise, vibration, and efficiency
  • Suitable for commercial and industrial applications

The fan sections are selected according to airflow, static pressure, and site conditions so that the system can be properly integrated into the overall HVAC system.

Technical Specifications

Fan Section TypesPlug Fans & Mixed Flow Fans
Size Range315 mm to 1600 mm
CapacityUp to 1,30,000 CMH
Static PressureUp to 40 mmWG
Plug Fan ImpellerAdjustable Pitch
Mixed Flow ImpellerBackward Curved
InstallationAHUs, HVAC Equipment & Duct Systems
ApplicationsCommercial & Industrial Spaces

The specific specifications and configuration depend on the requirements of the HVAC project. Airflow, static pressure, installation space, and application should be considered before the final selection.

Applications of Fan Sections

Industrial Fan Sections can be used in many commercial and industrial ventilation systems. Their compact design and flexible configurations make them appropriate for different types of air management requirements.

Air Handling Units

Fan sections may be integrated into AHUs to offer the specified air movement through the system. They can be selected according to the airflow and pressure requirements of the unit.

HVAC Systems

In industrial HVAC systems, fan sections help move conditioned air through ducts and other components. They can be used in new systems as well as replacement and retrofit projects.

Public Buildings

Mixed flow fan sections can be used in places such as hotels, auditoriums, railway stations, supermarkets, airports, washrooms, and other public areas.

Industrial Facilities

Factories and industrial facilities often require continuous ventilation. Fan sections can be configured to support air movement, supply air, or exhaust requirements depending on the system design.

Benefits of Fan Sections

Fan sections provide various practical advantages for HVAC and ventilation projects. Their ready-to-install design can simplify integration with air handling units and duct systems.

Another advantage is the availability of different fan configurations. Plug fans can provide a compact solution for system integration, while mixed flow fans can provide a balance of airflow and pressure.

The selection also can consider vital factors such as noise, vibration, durability, efficiency, safety, bulk, and weight. This makes it easier to develop a fan section according to the requirements of a specific installation.

Fan Sections Suppliers in Delhi

Choosing appropriate Fan Sections Suppliers in Delhi is important for projects where the fan section needs to integrate efficiently with existing or new HVAC equipment. The supplier should understand the specified airflow, static pressure, dimensions, and operating conditions.

For Delhi projects, fan sections are supplied for air handling units, existing AHU retrofits, and packaged HVAC equipment. The current product page states that units are selected according to airflow, static pressure, and site conditions, with technical sizing support available before ordering.

Fan Sections Manufacturer in India

A reliable Fan Sections Manufacturer in India must be capable of providing different configurations for commercial, industrial, and HVAC applications. Proper manufacturing and selection are critical because the fan section becomes a fundamental part of the whole air management system.

The production facility is located in Neemrana, Rajasthan, on the Delhi-Jaipur highway. This location gives convenient access for Delhi NCR projects, while completed units can also be dispatched to other parts of India.

How to Select the Right Fan Section?

Before selecting a fan section, consider the following factors:

  • Airflow requirement: Determine how much air the system needs to move.
  • Static pressure: Check the pressure required to overcome system resistance.
  • Available space: Select an appropriate configuration according to the installation area.
  • Fan type: Choose between plug fan and mixed flow fan based on the application.
  • Noise requirements: Consider the suitable noise level, especially in public and commercial areas.
  • Vibration: Proper fan selection supports stable operation.
  • Application: Consider whether the fan section will be installed in an AHU, HVAC system, commercial facility, or public building.

Correct sizing helps the fan section work efficiently with the entire ventilation system.

FAQs

What are fan sections used for?

Fan sections are used in AHUs, HVAC systems, packaged equipment, and ventilation systems to provide controlled air movement.

What types of fan sections are available?

The Delhi range includes Plug Fans and Mixed Flow Fans. Plug fans are designed for compact integration, while mixed flow fans combine axial and centrifugal characteristics.

What is the size range of the plug fan sections?

The listed size range is 315 mm to 1600 mm, with capacity up to 1,30,000 CMH and static pressure up to 40 mmWG.

Where can mixed flow fan sections be used?

Mixed flow fans may be used in washrooms, hotels, auditoriums, stations, supermarkets, airports, and other public areas. They can also be used for different HVAC and commercial applications.

Are fan sections suitable for AHU retrofits?

Yes. Fan sections may be used for existing AHU retrofits and new air handling and packaged HVAC equipment. The final configuration should be selected according to airflow, static pressure, dimensions, and location conditions.

Conclusion

Fan Sections Manufacturers in Delhi offer practical airflow solutions for AHUs, HVAC systems, packaged systems, and commercial ventilation applications. With plug fan and mixed flow fan options, different sizes, adjustable pitch impellers, and configurations designed for airflow and pressure requirements, these systems can be adapted to different project needs.

FanAir India Pvt. Ltd. offers fan sections for Delhi and NCR projects, such as new HVAC installations and AHU retrofit requirements. The system is manufactured at its Neemrana facility and can be supplied to Delhi as well as other places across India.

Contact Us

Serving Delhi NCR

Fan Air India Pvt. Ltd. manufactures ready-to-install fan sections with plug and mixed-flow fans. For customers in Delhi, our Fan Sections are commonly used for air handling units, retrofits of existing AHUs and packaged HVAC equipment.

Delhi NCR has a dense mix of commercial complexes, malls, hospitals, metro-linked developments and data centres, as well as industrial areas such as Okhla, Narela, Bawana and nearby Gurugram, Noida and Faridabad. Our manufacturing plant at Neemrana sits on the Delhi-Jaipur highway (NH-48), which keeps NCR projects close to the factory.

Every unit is built at our factory in Neemrana, Rajasthan and selected to suit the required airflow, static pressure and site conditions of your project. Our team can help with sizing and technical data before you order, and we dispatch finished equipment to sites across Delhi and the rest of India.

To get a quotation for Fan Sections in Delhi, share your airflow, pressure and application details through our contact page, call +91-9811347199 or email saurabh.joshi@fanair.in.

Other Fan Air products in Delhi

Fan Sections in other locations